fbpx
Belden 7965ENH Cat 6 Cable, U/UTP, LSZH, 4 Pair, AWG 23, Indoor CPR Eca Price in Dubai UAE

Belden 7965ENH Cat 6 Cable, U/UTP, LSZH, 4 Pair, AWG 23, Indoor CPR Eca Price in Dubai UAE

SKU : Belden 7965ENH Categories : , , Tag :

Inclusive of VAT

Description

Product Overview
Suitable Applications Horizontal and building backbone cable; Support current and future Category 6 and 5e applications, such as: 1000Base – T (Gigabit Ethernet), 100 Base – T, 10 Base – T, FDDI, ATM
Physical Characteristics (Overall)
CONDUCTOR
Element AWG Stranding Material No. of Pairs
Individual pair 23 Solid BC – Bare Copper 4
Conductor Count 8
Total Number of Pairs 4
INSULATION
Element Type Material Nominal Diameter
Individual pair Dielectric PE – Polyethylene 0.96 mm
Bonded-Pair No
COLOR CHART
Number Color
Pair 1 White/Blue & Blue
Pair 2 White/Green & Green
Pair 3 White/Orange & Orange
Pair 4 White/Brown & Brown
CABLING
Description Filler
4 pairs twisted together Cross Web of Polyolefin
OUTER JACKET MATERIAL
Material Nominal Diameter Diameter +/- Tolerance
LSZH – Low Smoke Zero Halogen (Flame Retardant) 5.4 mm 0.3 mm
Construction and Dimensions
Min Elongation at Breakof Conductors 10 %
Min Elongation at Breakof Insulation 100 %
Min Elongation at Breakof Jacket 100 %
Min Tensile Strength of Jacket 9 MPa
Electrical Characteristics
CONDUCTOR DCR
Max. Conductor DCR Max DCR Unbalanced Between Pairs [%] Max. DCR Unbalanced Within Pair [%]
95 Ohm/km 4 % 2 %
CAPACITANCE
Max. Capacitance Unbalance Max. Mutual Capacitance
1,600 pF/km 56 pF/m
IMPEDANCE
Nominal Characteristic Impedance
100 Ohm
DELAY
Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
40 ns/100m 70%
Table Notes Limits below 4 MHz are for information only. Reference standard: IEC 61156-5
General Electrical Parameters Notes Reference standard: ISO/IEC 61156-5
Coupling Attenuation Class Type III
Segregation class according EN50174-2 a
CURRENT
Max. Recommended Current [A]
1.5 Amps per Conductor
VOLTAGE
Voltage Rating [V]
72 V
Temperature Range
Installation Temp Range 0?C To +50?C
Operating Temp Range -30?C To +60?C
Mechanical Characteristics
Bulk Cable Weight 37 kg/km
Max. Pull Tension 80 N
Min. Bend Radius During Installation 46 mm
Min Bend Radius During Operation 23 mm
Standards
ISO/IEC Compliance ISO/IEC 11801-1
CPR Euroclass Eca
CENELEC Compliance EN 50173-1
Data Category Category 6
ANSI Compliance ANSI/TIA 568.2-D (2018)
IEEE Compliance PoE: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Applicable Environmental and Other Programs
Environmental Space Indoor – Euroclass Eca
EU RoHS Compliance Date (yyyy-mm-dd) 2004-01-01
Flammability, LS0H, Toxicity Testing
IEC Flammability IEC 60332-1-2
Burning Load 455 kJ/m
IEC 60754-1 – Halogen Amount Zero
IEC 60754-2 – Halogen Acid Gas Amount – Max. Conductivity 2.5 ?S/mm
IEC 60754-2 – Halogen Acid Gas Amount – Min. pH 4.3
IEC 61034-2 – Smoke Density Min. Transmittance 60%
Product Notes
Notes Electrical values are expected performance based on cable testing and representative performance within a typical Belden system.
History
Update and Revision Revision Number: 0.261 Revision Date: 08-27-2021

Vendor Information

  • No ratings found yet!

Product Enquiry

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy